What Fleet Operators Need to Know: UL 1564 Explained

Industrial battery charger safety is important to consider with your electric fleet. Learn more about the UL certification process and what you should verify when deciding on charging equipment.

Enatel power system mounted on a concrete wall with battery connection display and nearby fire action sign.

Safety is essential for any material handling or ground support equipment operation. Fleet managers routinely consider whether their forklifts, belt loaders, and other off-highway vehicles meet appropriate safety standards. But as more vehicles are electrified, operators should also consider the compliance of the industrial battery chargers that support these vehicles.  

Charger testing and certification provide important evidence that a battery charger has been tested against defined safety requirements by an independent third party. For material handling equipment chargers, one of the most relevant standards is UL 1564.  

This article will explore the topics fleet operators need to understand when it comes to battery charger compliance and UL 1564, including:  

What are Nationally Recognized Testing Laboratories? 

Before examining UL 1564 in more detail, it is first important to understand the difference between a testing laboratory and a standards developer.  

A Nationally Recognized Testing Laboratory is an independent, third-party organization that is empowered by the U.S. Occupational Safety & Health Administration (OSHA) to evaluate and certify products to consensus-based safety standards. These standards are developed by organizations like UL, CSA, and others. In other words, UL serves as both an NRTL and a standards developer for itself and other NRTLs. 

NRTLs are the only organizations allowed to legally test product safety across the United States and Canada. To receive OSHA recognition, an NRTL must meet the legal requirements in 29 CFR 1910.7. This covers requirements such as demonstrating appropriate testing capability, conducting in-person factory/product line inspections, remaining unbiased and independent, and more. 

There are over twenty Nationally Recognized Testing Laboratories, including CSA, Eurofins, Intertek, TÜV Rheinland, UL, and more. Each individual NRTL has an associated “mark”, or a simple, easily recognizable symbol. When this mark appears on a component or product, it signifies that specific NRTL has tested the product to appropriate safety standards.  

What is UL compliance? 

UL standards are published safety benchmarks used both by UL and other NRTLs to test products and components. When it comes to the industrial off-highway vehicle market, a few key standards are important to remember that cover the truck itself, its battery, and its charger: 

This standard covers safety in battery electric powered industrial trucks, including evaluating the risk of fire, electric shock, and explosion. It also covers the safety of lead-acid batteries used in industrial trucks, as well as the suitability of a truck for use in hazardous environments.  

This standard addresses the batteries used in many types of vehicles, including lithium-ion and other non-lead acid chemistries in industrial trucks. It evaluates the entire battery’s electrical, mechanical, and environmental performance for safety, as well as individual components like wiring and fuses. UL 2271 is a similar standard used for batteries in some smaller equipment. 

This standard is used to evaluate industrial battery chargers with a rated input voltage of 600VAC or less. This includes chargers used with industrial trucks like forklifts, but does not include chargers for on-highway vehicles or starter batteries. In addition to charger design requirements, the standard also requires the product to undergo rigorous safety testing. UL 1564 is intended to be used in accordance with the National Electrical Code (NFPA 70). 

Canada has its own national safety standards for industrial battery chargers. Within the country, CAN/CSA 22.2 No. 107.2 is the national safety standard for industrial fleet charging solutions. Most NRTLs include a subscript “C” to the left of their mark to indicate that a charger is also listed to Canadian standards.

A long, brightly lit warehouse aisle lined with tall orange-and-steel pallet racks filled with cardboard boxes on wooden pallets. A small forklift or pallet jack is parked in the center foreground, with a person visible in the distance between the shelves.

What does UL testing for industrial battery chargers involve? 

UL 1564 is a rigorous safety standard that requires an NRTL to evaluate a charger’s design and test product samples. The review and testing process first identifies critical parts of the charger’s construction. These parts are clearly documented, and the NRTL inspects production of the charger at the manufacturer’s facility on a quarterly basis to ensure they remain unchanged.  

UL 1564 also lists specific requirements that the manufacturer must implement in the charger’s design to meet the standard. Each requirement is meant to improve product safety and reduce the risk of fire, mechanical, and electrical hazards. This includes design considerations surrounding:  

  • The charger’s enclosure strength and protection from hazardous energy 
  • Flammability and flame retardance of materials used 
  • AC input and DC output cables and cable strain relief 
  • Spacings and insulation barriers 
  • Construction of transformers, coils, and other components 

Once the charger is designed, UL 1564 also requires extensive testing of charger samples. The purpose of such testing is not to guarantee a product will never fail. Rather, the testing confirms that it did not fail in a dangerous manner after it was pushed to its limits (no hazardous shocks, fires, explosions, etc.).  

Product tests required include: 

  • Earth leakage current, including after humidity conditioning 
  • Power consumption 
  • Temperature rise of parts under load 
  • Abnormal operation tests that examine how the charger operates under conditions like short circuits, reverse polarity in the battery, and more 
  • Mechanical tests, including when a charger is tipped over, dropped, or hit 
  • Earth bonding  

The standard also includes two annexes with additional requirements for chargers that will be used outdoors (Annex A) or with lithium-ion batteries (Annex B). 

How can you tell whether an industrial battery charger is certified? 

To know whether a charger has undergone this third-party testing, operators should scrutinize the charger itself. Chargers that are tested to UL 1564 will include the mark of the NRTL that evaluated it somewhere on the product, as well as the text “INDUSTRIAL BATTERY CHARGER.” Chargers that have passed Annex A (outdoor charging) will also be marked as “RAINPROOF” or “RAINTIGHT,” while chargers that have passed Annex B (Li-Ion) will be marked with a lithium-ion battery type. 

Another method to determine a charger’s compliance is by looking up the product’s listing in the NRTL’s product directory.  Many NRTLs include a directory on their website that shows the manufacturer’s name, model name/number, the standard it was tested to, and the certification mark it received. For example, Enatel industrial battery chargers are listed in UL’s product directory here. 

Why should you choose a compliant industrial battery charger? 

Across regions such as Europe, forklift battery charger compliance is required and expected for market entry. On the other hand, some fleet managers in the North American region may not even be aware of charger standards like UL 1564 or what it involves. Others may simply look at the charger’s price tag and choose the cheapest option—even if that charger was not tested by an NRTL. 

Close-up of electronic equipment with grey and green design, featuring a screen and control buttons, branded with 'Enatel'.

However, in many cases, an NRTL-listed battery charger is needed to meet OSHA and NEC obligations. A charger’s compliance with UL 1564 is also an effective way for employers to demonstrate that they meet 29 CFR 1910.303 and adjacent clauses. CFR 1910.303 describes requirements for electrical equipment safety, such as ensuring the integrity of wiring insulation and firmly securing the equipment to the surface where it is mounted.  

For these reasons, UL 1564 compliance is important to consider when deciding on a charger. While non-compliant chargers do not equate to unsafe chargers, compliant chargers provide fleet operators with two key benefits: 

  • Peace of Mind and Charging Confidence: An NRTL mark indicates that a charger was independently tested and verified by a third party. Operators can rest assured that compliant chargers were subjected to rigorous safety testing by an unbiased, external organization. Compliance thus provides added confidence that charging infrastructure will perform as expected over the long term. 
  • Demonstrate Care for Employee Safety: Purchasing compliant industrial battery chargers also helps fleet managers indicate they care about employee safety. On the slim chance that the charger unexpectedly malfunctions and causes an injury, a compliant charger also provides compelling evidence that an operator took due care to obtain a safe and reliable product.  

Are Enatel chargers UL-compliant? 

Ensuring that our charging solutions meet safety and compliance standards is a key focus. The Enatel Indoor Charger and Enatel Outdoor Charger are manufactured to meet important global compliance standards like UL 1564. Enatel’s standout field failure rate of less than 1% demonstrates the rigorous testing and quality controls built into each stage of our manufacturing process.  

  • Global Compliance: Enatel chargers feature UL, cUL, FCC, IC, CE, UKCA, RCM, and Giteki approvals. Our chargers have passed rigorous performance testing for electromagnetic compatibility (EMC), radio compliance, efficiency, cybersecurity, safety, and more. 
  • Proven Durability: The Enatel Outdoor Charger is also rated to meet ingress protection standards such as NEMA 250 and IP54, ensuring the outdoor industrial battery charger will withstand harsh weather conditions. 

Additionally, our manufacturing and production hub in Christchurch, New Zealand, is regularly inspected by UL representatives to ensure the charger construction process matches testing requirements.  

Enatel is also in the process of constructing its own lab with UL testing capabilities. Once complete, we will be one of a select few charger manufacturers that are certified to conduct such testing.  

Why UL 1564 Certification Matters  

As fleets continue to electrify, operators should remember to consider compliance when selecting a charger for their material handling or ground support equipment fleets. An NRTL mark provides valuable evidence that a charger has passed third-party safety testing. For operators looking to improve their confidence in fleet (and employee) safety, compliance provides one important solution.